Mode pages (not related to any transport protocol or vendor): addp 0x0e,0x02 DT device primary port (ADC) adlu 0x0e,0x03 logical unit (ADC) adtd 0x0e,0x01 Target device (ADC) adts 0x0e,0x04 Target device serial number (ADC) afc 0x0a,0xf2 SAT ATA Feature control apo 0x1a,0xf1 SAT ATA Power condition atag 0x0a,0x02 Application tag (SBC) bc 0x1c,0x01 Background control (SBC) bop 0x0a,0x06 Background operation control (SBC) ca 0x08 Caching (SBC) cdla 0x0a,0x03 Command duration limit A cdlb 0x0a,0x04 Command duration limit B cdt2a 0x0a,0x07 Command duration limit T2A cdt2b 0x0a,0x08 Command duration limit T2B cms 0x2a CD/DVD (MM) capabilities and mechanical status (MMC) co 0x0a Control coe 0x0a,0x01 Control extension cdp 0x0a,0xf0 Control data protection (SSC) dac 0x0f Data compression (SSC) dc 0x10 Device configuration (SSC) dca 0x1f Device capabilities (SMC) dce 0x10,0x01 Device configuration extension (SSC) dr 0x02 Disconnect-reconnect (SPC + transports) eaa 0x1d Element address assignment (SMC) edc 0x1f,0x41 Extended device capabilities (SMC) esm 0x14 Enclosure services management (SES) fd 0x05 Flexible disk (SBC) fo 0x03 Format (SBC) ie 0x1c Informational exceptions control ioad 0x0a,0x05 IO advice hints grouping lbp 0x1c,0x02 Logical block provisioning (SBC) mco 0x1d Medium configuration (SSC) mpa 0x11 Medium partition (SSC) mrw 0x03 Mount rainier reWritable (MMC) not 0x0c Notch and partition (SBC) pat 0x0a,0xf1 SAT pATA control pl 0x18 Protocol specific logical unit po 0x1a Power condition ps 0x1a,0x01 Power consumption poo 0x0d Power condition - old version pp 0x19 Protocol specific port rbc 0x06 RBC device parameters (RBC) rd 0x04 Rigid disk (SBC) rw 0x01 Read write error recovery tgp 0x1e Transport geometry parameters (SMC) tp 0x1d Timeout and protect (MMC) ve 0x07 Verify error recovery (SBC) wp 0x05 Write parameters (MMC) xo 0x10 XOR control (SBC) zbdct 0x0a,0x0f Zoned block device control (ZBC) Transport protocols: fcp 0x00 Fibre Channel Protocol for SCSI (FCP-5) spi,para 0x01 SCSI Parallel Interface (SPI-5) ssa 0x02 Serial Storage Architecture SCSI-3 Protocol (SSA-S3P) sbp 0x03 Serial Bus Protocol for IEEE 1394 (SBP-3) srp,ib 0x04 SCSI RDMA Protocol (SRP) iscsi 0x05 Internet SCSI (iSCSI) sas,spl 0x06 Serial Attached SCSI Protocol (SPL-4) adt 0x07 Automation/Drive Interface Transport (ADT-2) ata,sata 0x08 AT Attachment Interface (ACS-2) uas,usb 0x09 USB Attached SCSI (UAS-2) sop 0x0a SCSI over PCI Express (SOP) pcie,nvme 0x0b PCIe u0xc 0x0c Oxc u0xd 0x0d Oxd u0xe 0x0e Oxe none 0x0f No specific protocol Vendors: sea 0x00 Seagate disk hit 0x01 Hitachi disk wdc 0x01 Hitachi disk->HGST->WDC max 0x02 Maxtor disk fuj 0x03 Fujitsu disk lto5 0x05 LTO-5 tape drive (IBM, HP) lto6 0x06 LTO-6 tape drive (IBM, HP) nvme 0x07 NVMe, SNTL in library sg 0x08 sg3_utils package defined Read write error recovery [rw: 0x1] [bad pdt] mode page: AWRE [0x02:7:1 ] Automatic write reallocation enabled ARRE [0x02:6:1 ] Automatic read reallocation enabled TB [0x02:5:1 ] Transfer block RC [0x02:4:1 ] Read continuous EER [0x02:3:1 ] Enable early recovery (obsolete) PER [0x02:2:1 ] Post error DTE [0x02:1:1 ] Data terminate on error DCR [0x02:0:1 ] Disable correction (obsolete) RRC [0x03:7:8 ] Read retry count COR_S [0x04:7:8 ] Correction span (obsolete) HOC [0x05:7:8 ] Head offset count (obsolete) DSOC [0x06:7:8 ] Data strobe offset count (obsolete) LBPERE [0x07:7:1 ] Logical block provisioning error reporting enabled MWR [0x07:6:2 ] Misaligned write reporting EMCDR [0x07:1:2 ] Enhanced media certification and defect reporting WRC [0x08:7:8 ] Write retry count ERWS [0x09:7:24] Error reporting window size (blocks) RTL [0x0a:7:16] Recovery time limit (ms) Disconnect-reconnect (SPC + transports) [dr: 0x2] [bad pdt] mode page: BFR [0x02:7:8 ] Buffer full ratio BER [0x03:7:8 ] Buffer empty ratio BIL [0x04:7:16] Bus inactivity limit DTL [0x06:7:16] Disconnect time limit CTL [0x08:7:16] Connect time limit MBS [0x0a:7:16] Maximum burst size (512 bytes) EMDP [0x0c:7:1 ] Enable modify data pointers FA [0x0c:6:3 ] Fair arbitration DIMM [0x0c:3:1 ] Disconnect immediate DTDC [0x0c:2:3 ] Data transfer disconnect control FBS [0x0e:7:16] First burst size (512 bytes) Format (SBC) [fo: 0x3] [disk] mode page: TPZ [0x02:7:16] Tracks per zone ASPZ [0x04:7:16] Alternate sectors per zone ATPZ [0x06:7:16] Alternate tracks per zone ATPLU [0x08:7:16] Alternate tracks per logical unit SPT [0x0a:7:16] Sectors per track DBPPS [0x0c:7:16] Data bytes per physical sector INTLV [0x0e:7:16] Interleave TSF [0x10:7:16] Track skew factor CSF [0x12:7:16] Cylinder skew factor SSEC [0x14:7:1 ] Soft sector HSEC [0x14:6:1 ] Hard sector RMB [0x14:5:1 ] Removable SURF [0x14:4:1 ] Surface Mount rainier reWritable (MMC) [mrw: 0x3] [cd/dvd] mode page: LBAS [0x03:0:1 ] LBA space Rigid disk (SBC) [rd: 0x4] [disk] mode page: NOC [0x02:7:24] Number of cylinders NOH [0x05:7:8 ] Number of heads SCWP [0x06:7:24] Starting cylinder for write precompensation SCRWC [0x09:7:24] Starting cylinder for reduced write current DSR [0x0c:7:16] Device step rate LZC [0x0e:7:24] Landing zone cylinder RPL [0x11:1:2 ] Rotational position locking ROTO [0x12:7:8 ] Rotational offset MRR [0x14:7:16] Medium rotation rate (rpm) Flexible disk (SBC) [fd: 0x5] [disk] mode page: XRATE [0x02:7:16] Transfer rate NUM_HD [0x04:7:8 ] Number of heads SECT_TR [0x05:7:8 ] Sectors per track BYTE_SECT [0x06:7:16] Bytes per sector NUM_CYL [0x08:7:16] Number of cylinders Write parameters (MMC) [wp: 0x5] [cd/dvd] mode page: BUFE [0x02:6:1 ] Buffer underrun free recording enable LS_V [0x02:5:1 ] Link size valid TST_W [0x02:4:1 ] Test write WR_T [0x02:3:4 ] Write type MULTI_S [0x03:7:2 ] Multi session FP [0x03:5:1 ] Fixed packet type COPY [0x03:4:1 ] Serial copy management system (SCMS) enable TRACK_M [0x03:3:4 ] Track mode DBT [0x04:3:4 ] Data block type LINK_S [0x05:7:8 ] Link size IAC [0x07:5:6 ] Initiator application code SESS_F [0x08:7:8 ] Session format PACK_S [0x0a:7:32] Packet size APL [0x0e:7:16] Audio pause length (blocks) RBC device parameters (RBC) [rbc: 0x6] [simplified direct access device] mode page: WCD [0x02:0:1 ] Write cache disable LBS [0x03:7:16] Logical block size NLBS [0x05:7:40] Number of logical blocks P_P [0x0a:7:8 ] Power/performance READD [0x0b:3:1 ] Read disable WRITED [0x0b:2:1 ] Write disable FORMATD [0x0b:1:1 ] Format disable LOCKD [0x0b:0:1 ] Lock disable Verify error recovery (SBC) [ve: 0x7] [bad pdt] mode page: V_EER [0x02:3:1 ] Enable early recovery (obsolete) V_PER [0x02:2:1 ] Post error V_DTE [0x02:1:1 ] Data terminate on error V_DCR [0x02:0:1 ] Disable correction (obsolete) V_RC [0x03:7:8 ] Verify retry count V_COR_S [0x04:7:8 ] Verify correction span (obsolete) V_RTL [0x0a:7:16] Verify recovery time limit (ms) Caching (SBC) [ca: 0x8] [bad pdt] mode page: IC [0x02:7:1 ] Initiator control ABPF [0x02:6:1 ] Abort pre-fetch CAP [0x02:5:1 ] Caching analysis permitted DISC [0x02:4:1 ] Discontinuity SIZE [0x02:3:1 ] Size enable WCE [0x02:2:1 ] Write cache enable MF [0x02:1:1 ] Multiplication factor RCD [0x02:0:1 ] Read cache disable DRRP [0x03:7:4 ] Demand read retention priority WRP [0x03:3:4 ] Write retention priority DPTL [0x04:7:16] Disable pre-fetch transfer length MIPF [0x06:7:16] Minimum pre-fetch MAPF [0x08:7:16] Maximum pre-fetch MAPFC [0x0a:7:16] Maximum pre-fetch ceiling FSW [0x0c:7:1 ] Force sequential write LBCSS [0x0c:6:1 ] Logical block cache segment size DRA [0x0c:5:1 ] Disable read ahead SYNC_PROG [0x0c:2:2 ] Synchronous cache progress indication NV_DIS [0x0c:0:1 ] Non-volatile cache disable NCS [0x0d:7:8 ] Number of cache segments CSS [0x0e:7:16] Cache segment size Control [co: 0xa] [bad pdt] mode page: TST [0x02:7:3 ] Task set type TMF_ONLY [0x02:4:1 ] Task management functions only DPICZ [0x02:3:1 ] Disable protection information check if protect field zero D_SENSE [0x02:2:1 ] Descriptor format sense data GLTSD [0x02:1:1 ] Global logging target save disable RLEC [0x02:0:1 ] Report log exception condition QAM [0x03:7:4 ] Queue algorithm modifier NUAR [0x03:3:1 ] No unit attention on release QERR [0x03:2:2 ] Queue error management VS_CTL [0x04:7:1 ] Vendor specific [byte 4, bit 7] RAC [0x04:6:1 ] Report a check UA_INTLCK [0x04:5:2 ] Unit attention interlocks control SWP [0x04:3:1 ] Software write protect ATO [0x05:7:1 ] Application tag owner TAS [0x05:6:1 ] Task aborted status ATMPE [0x05:5:1 ] Application tag mode page enabled RWWP [0x05:4:1 ] Reject write without protection SBLP [0x05:3:1 ] Supported block lengths and protection information AUTOLOAD [0x05:2:3 ] Autoload mode BTP [0x08:7:16] Busy timeout period (100us) ESTCT [0x0a:7:16] Extended self test completion time (sec) Control extension [coe: 0xa,0x1] [bad pdt] mode page: DLC [0x04:3:1 ] Device life control TCMOS [0x04:2:1 ] Timestamp changeable by methods outside standard SCSIP [0x04:1:1 ] SCSI timestamp commands take precedence over other methods IALUAE [0x04:0:1 ] Implicit asymmetric logical unit access enabled INIT_PR [0x05:3:4 ] Initial command priority MSDL [0x06:7:8 ] Maximum sense data length NSQCC [0x07:7:8 ] Non-sequestered command count SQCO [0x08:7:8 ] Sequestered command order Application tag (SBC) [atag: 0xa,0x2] [bad pdt] mode page: AT_LAST [0x10:7:1 ] Last AT_LBAT [0x16:7:16] Logical block application tag AT_LBA [0x18:7:64] Logical block address AT_COUNT [0x20:7:64] Logical block count Command duration limit A [cdla: 0xa,0x3] [bad pdt] mode page: CDA_UNIT [0x08:7:3 ] CDLA unit CDA_LIMIT [0x0a:7:16] Command duration limit Command duration limit B [cdlb: 0xa,0x4] [bad pdt] mode page: CDB_UNIT [0x08:7:3 ] CDL unit CDB_LIMIT [0x0a:7:16] Command duration limit IO advice hints grouping [ioad: 0xa,0x5] [bad pdt] mode page: IOA_MODE [0x10:7:2 ] IO advice hints mode CS_EN [0x10:1:1 ] Cache segment enable IC_EN [0x10:0:1 ] Information collection enable ACDLU [0x14:7:1 ] Access continue during low utilization RLBSR [0x14:5:2 ] Related logical blocks and subsequent reads LBM_DT [0x14:3:4 ] LBM descriptor type OV_FR [0x15:7:2 ] Overall frequency RW_FR [0x15:5:2 ] Read/write frequency WR_SE [0x15:3:2 ] Write sequentiality RD_SE [0x15:1:2 ] Read sequentiality IO_CL [0x16:7:4 ] IO class SU_IO [0x16:3:2 ] Subsequent I/O OSI_PR [0x16:1:2 ] Operating System Initialization (OSI) proximity Background operation control (SBC) [bop: 0xa,0x6] [disk] mode page: BO_MODE [0x04:7:2 ] Background operation mode Command duration limit T2A [cdt2a: 0xa,0x7] [bad pdt] mode page: PVCDG [0x07:7:4 ] Perf versus command duration guidelines T2CDLU [0x08:3:4 ] T2 command duration limit units MXINATI [0x0a:7:16] Max inactive time MXACTTI [0x0c:7:16] Max active time MXINATP [0x0e:7:4 ] Max inactive time policy MXACTTP [0x0e:3:4 ] Max active time policy CDGUID [0x12:7:16] Command duration guideline CDGUPOL [0x16:7:16] Command duration guideline policy BYP_SEQ [0x17:0:1 ] Bypass sequestration Command duration limit T2B [cdt2b: 0xa,0x8] [bad pdt] mode page: PVLC [0x07:3:4 ] Perf versus latency control T2CDLU [0x08:3:4 ] T2 command duration limit units MXINATI [0x0a:7:16] Max inactive time MXACTTI [0x0c:7:16] Max active time MXINATP [0x0e:7:4 ] Max inactive time policy MXACTTP [0x0e:3:4 ] Max active time policy CDGUID [0x12:7:16] Command duration guideline CDGUPOL [0x16:7:16] Command duration guideline policy BYP_SEQ [0x17:0:1 ] Bypass sequestration Zoned block device control (ZBC) [zbdct: 0xa,0xf] [bad pdt] mode page: URSWRZ_M [0x04:0:1 ] Unrestricted read in sequential write required management U_UA_CTL [0x05:0:1 ] Unrestricted read in sequential write required zone unit attention control Control data protection (SSC) [cdp: 0xa,0xf0] [tape] mode page: LBPM [0x04:7:8 ] Logical block protection method LBPIL [0x05:5:6 ] Logical block protection information length LBP_W [0x06:7:1 ] Logical block protection during write LBP_R [0x06:6:1 ] Logical block protection during read RBDP [0x06:5:1 ] Recover buffered data protected SAT pATA control [pat: 0xa,0xf1] [bad pdt] mode page: MWD2 [0x04:6:1 ] Multi word DMA bit 2 MWD1 [0x04:5:1 ] Multi word DMA bit 1 MWD0 [0x04:4:1 ] Multi word DMA bit 0 PIO4 [0x04:1:1 ] Parallel IO bit 4 PIO3 [0x04:0:1 ] Parallel IO bit 3 UDMA6 [0x05:6:1 ] Ultra DMA bit 6 UDMA5 [0x05:5:1 ] Ultra DMA bit 5 UDMA4 [0x05:4:1 ] Ultra DMA bit 4 UDMA3 [0x05:3:1 ] Ultra DMA bit 3 UDMA2 [0x05:2:1 ] Ultra DMA bit 2 UDMA1 [0x05:1:1 ] Ultra DMA bit 1 UDMA0 [0x05:0:1 ] Ultra DMA bit 0 SAT ATA Feature control [afc: 0xa,0xf2] [bad pdt] mode page: CDL_CTRL [0x04:1:2 ] Command duration limits control Notch and partition (SBC) [not: 0xc] [disk] mode page: ND [0x02:7:1 ] Notched device LPN [0x02:6:1 ] Logical or physical notch MNN [0x04:7:16] Maximum number of notches ANOT [0x06:7:16] Active notch SBOU [0x08:7:32] Starting boundary EBOU [0x0c:7:32] Ending boundary PNOT [0x10:7:64] Pages notched Power condition - old version [poo: 0xd] [disk] mode page: IDLE-OLD [0x03:1:1 ] Idle timer active STBY-OLD [0x03:0:1 ] Standby timer active ICT-OLD [0x04:7:32] Idle condition timer (100 ms) SCT-OLD [0x08:7:32] Standby condition timer (100 ms) Data compression (SSC) [dac: 0xf] [tape] mode page: DCE [0x02:7:1 ] Data compression enable DCC [0x02:6:1 ] Data compression capable DDE [0x03:7:1 ] Data decompression enable RED [0x03:6:2 ] Report exception on decompression COMPR_A [0x04:7:32] Compression algorithm DCOMPR_A [0x08:7:32] Decompression algorithm XOR control (SBC) [xo: 0x10] [disk] mode page: XORDIS [0x02:1:1 ] XOR disable MXWS [0x04:7:32] Maximum XOR write size (blocks) Device configuration (SSC) [dc: 0x10] [tape] mode page: CAF [0x02:5:1 ] Change active format ACT_F [0x02:4:5 ] Active format ACT_P [0x03:7:8 ] Active partition WOBFR [0x04:7:8 ] Write object buffer full ratio ROBER [0x05:7:8 ] Read object buffer empty ratio WDT [0x06:7:16] Write delay time (100 ms) OBR [0x08:7:1 ] Object buffer recovery LOIS [0x08:6:1 ] Logical object identifiers supported RSMK [0x08:5:1 ] Report setmarks (obsolete) AVC [0x08:4:1 ] Automatic velocity control SOCF [0x08:3:2 ] Stop on consecutive filemarks ROBO [0x08:1:1 ] Recover object buffer order REW [0x08:0:1 ] Report early warning GAP_S [0x09:7:8 ] Gap size (obsolete) EOD_D [0x0a:7:3 ] EOD (end-of-data) defined EEG [0x0a:4:1 ] Enable EOD generation SEW [0x0a:3:1 ] Synchronize early warning SWP_T [0x0a:2:1 ] Software write protect (tape) BAML [0x0a:1:1 ] Block address mode lock BAM [0x0a:0:1 ] Block address mode OBSAEW [0x0b:7:24] Object buffer size at early warning SDCA [0x0e:7:8 ] Select data compression algorithm WTRE [0x0f:7:2 ] WORM tamper read enable OIR [0x0f:5:1 ] Only if reserved ROR [0x0f:4:2 ] Rewind on reset ASOCWP [0x0f:2:1 ] Associated write protection PERSWP [0x0f:1:1 ] Persistent write protection PRMWP [0x0f:0:1 ] Permanent write protection Device configuration extension (SSC) [dce: 0x10,0x1] [tape] mode page: PE_UN [0x04:7:4 ] PEWS units TARPF [0x04:3:1 ] TapeAlert respect parameter fields TASER [0x04:2:1 ] TapeAlert select except reporting TARPC [0x04:1:1 ] TapeAlert respect page control TAPLSD [0x04:0:1 ] TapeAlert prevent log sense deactivation WR_MOD [0x05:7:4 ] Write mode SEM [0x05:3:4 ] Short erase mode PEWS [0x06:7:16] Programmable early warning size VCELBRE [0x08:0:1 ] Volume containing encrypted logical blocks requires encryption Medium partition (SSC) [mpa: 0x11] [tape] mode page: MAX_AP [0x02:7:8 ] Maximum additional partitions APD [0x03:7:8 ] Additional partitions defined FDP [0x04:7:1 ] Fixed data partitions SDP [0x04:6:1 ] Select data partitions IDP [0x04:5:1 ] Initiator defined partitions PSUM [0x04:4:2 ] Partition size unit of measure POFM [0x04:2:1 ] Partition on format CLEAR [0x04:1:1 ] Erase partition(s) (in concert with ADDP) ADDP [0x04:0:1 ] Additional partition bit (in concert with CLEAR) MFR [0x05:7:8 ] Medium format recognition PART_T [0x06:7:4 ] Partition type PART_U [0x06:3:4 ] Partition units (exponent of 10, bytes) P_SZ [0x08:7:16] Partition size Enclosure services management (SES) [esm: 0x14] [enclosure services device] mode page: ENBLTC [0x05:0:1 ] Enable timed completion MTCT [0x06:7:16] Maximum task completion time (100ms) Protocol specific logical unit [pl: 0x18] [bad pdt] mode page: LUPID [0x02:3:4 ] Logical unit's (transport) protocol identifier Protocol specific port [pp: 0x19] [bad pdt] mode page: PPID [0x02:3:4 ] Port's (transport) protocol identifier Power condition [po: 0x1a] [bad pdt] mode page: PM_BG [0x02:7:2 ] Power management, background functions, precedence STANDBY_Y [0x02:0:1 ] Standby_y timer enable IDLE_C [0x03:3:1 ] Idle_c timer enable IDLE_B [0x03:2:1 ] Idle_b timer enable IDLE_A [0x03:1:1 ] Idle_a timer enable STANDBY_Z [0x03:0:1 ] Standby_z timer enable IACT [0x04:7:32] Idle_a condition timer (100 ms) SZCT [0x08:7:32] Standby_z condition timer (100 ms) IBCT [0x0c:7:32] Idle_b condition timer (100 ms) ICCT [0x10:7:32] Idle_c condition timer (100 ms) SYCT [0x14:7:32] Standby_y condition timer (100 ms) CCF_IDLE [0x27:7:2 ] check condition if from idle_c CCF_STAND [0x27:5:2 ] check condition if from a standby CCF_STOPP [0x27:3:2 ] check condition if from stopped Power consumption [ps: 0x1a,0x1] [bad pdt] mode page: ACT_LEV [0x06:1:2 ] Active level PC_ID [0x07:7:8 ] Power consumption identifier SAT ATA Power condition [apo: 0x1a,0xf1] [bad pdt] mode page: APMP [0x05:0:1 ] Advanced Power Management (APM) enabled/change APM [0x06:7:8 ] Advanced Power Management (APM) value Informational exceptions control [ie: 0x1c] [bad pdt] mode page: PERF [0x02:7:1 ] Performance (impact of ie operations) EBF [0x02:5:1 ] Enable background function EWASC [0x02:4:1 ] Enable warning DEXCPT [0x02:3:1 ] Disable exceptions TEST [0x02:2:1 ] Test (simulate device failure) EBACKERR [0x02:1:1 ] Enable background (scan + self test) error reporting LOGERR [0x02:0:1 ] Log informational exception errors MRIE [0x03:3:4 ] Method of reporting informational exceptions INTT [0x04:7:32] Interval timer (100 ms) REPC [0x08:7:32] Report count (or Test flag number [SSC-3]) Background control (SBC) [bc: 0x1c,0x1] [bad pdt] mode page: S_L_FULL [0x04:2:1 ] Suspend on log full LOWIR [0x04:1:1 ] Log only when intervention required EN_BMS [0x04:0:1 ] Enable background medium scan EN_PS [0x05:0:1 ] Enable pre-scan BMS_I [0x06:7:16] Background medium scan interval time (hour) BPS_TL [0x08:7:16] Background pre-scan time limit (hour) MIN_IDLE [0x0a:7:16] Minumum idle time before background scan (ms) MAX_SUSP [0x0c:7:16] Maximum time to suspend background scan (ms) Logical block provisioning (SBC) [lbp: 0x1c,0x2] [disk] mode page: SITUA [0x04:0:1 ] Single initiator threshold unit attention LBP_EN [0x10:7:1 ] Threshold enabled LBP_TYPE [0x10:5:3 ] Threshold type LBP_ARM [0x10:2:3 ] Threshold arming LBP_RES [0x11:7:8 ] Threshold resource LBP_COUNT [0x14:7:32] Threshold count Medium configuration (SSC) [mco: 0x1d] [tape] mode page: WORMM [0x02:0:1 ] Worm mode WMLR [0x04:7:8 ] Worm volume label restrictions WMFR [0x05:7:8 ] Worm volume filemark restrictions Timeout and protect (MMC) [tp: 0x1d] [cd/dvd] mode page: G3E [0x04:3:1 ] Group 3 timeout capability enable TMOE [0x04:2:1 ] Timeout enable DISP [0x04:1:1 ] Disable (unavailable) until power cycle SWPP [0x04:0:1 ] Software write protect until power cycle G1MT [0x06:7:16] Group 1 minimum timeout (sec) G2MT [0x08:7:16] Group 2 minimum timeout (sec) Element address assignment (SMC) [eaa: 0x1d] [medium changer] mode page: FMTEA [0x02:7:16] First medium transport element address NMTE [0x04:7:16] Number of medium transport elements FSEA [0x06:7:16] First storage element address NSE [0x08:7:16] Number of storage elements FIEEA [0x0a:7:16] First import/export element address NIEE [0x0c:7:16] Number of import/export elements FDTEA [0x0e:7:16] First data transfer element address NDTE [0x10:7:16] Number of data transfer elements Transport geometry parameters (SMC) [tgp: 0x1e] [medium changer] mode page: ROTAT [0x02:0:1 ] Rotation for double sided media handling MNTES [0x03:7:8 ] Member number in transport element set Device capabilities (SMC) [dca: 0x1f] [medium changer] mode page: STORDT [0x02:3:1 ] Storage for data transfer element STORIE [0x02:2:1 ] Storage for import/export element STORST [0x02:1:1 ] Storage for storage element STORMT [0x02:0:1 ] Storage for medium transport element ACE [0x03:2:1 ] Auto clean enabled VTRP [0x03:1:1 ] Volume tag reader present S2C [0x03:0:1 ] SMC-2 capabilities supported MT_RA [0x04:7:2 ] Medium transport elements support Read Attribute MT2DT [0x04:3:1 ] Medium transport -> data transfer; Move Medium MT2IE [0x04:2:1 ] Medium transport -> import/export; Move Medium MT2ST [0x04:1:1 ] Medium transport -> storage; Move Medium MT2MT [0x04:0:1 ] Medium transport -> medium transport; Move Medium ST_RA [0x05:7:2 ] Storage elements support Read Attribute ST2DT [0x05:3:1 ] Storage -> data transfer; Move Medium ST2IE [0x05:2:1 ] Storage -> import/export; Move Medium ST2ST [0x05:1:1 ] Storage -> storage; Move Medium ST2MT [0x05:0:1 ] Storage -> medium transport; Move Medium IE_RA [0x06:7:2 ] Import/export elements support Read Attribute IE2DT [0x06:3:1 ] Import/export -> data transfer; Move Medium IE2IE [0x06:2:1 ] Import/export -> import/export; Move Medium IE2ST [0x06:1:1 ] Import/export -> storage; Move Medium IE2MT [0x06:0:1 ] Import/export -> medium transport; Move Medium DT_RA [0x07:7:2 ] Data transfer elements support Read Attribute DT2DT [0x07:3:1 ] Data transfer -> data transfer; Move Medium DT2IE [0x07:2:1 ] Data transfer -> import/export; Move Medium DT2ST [0x07:1:1 ] Data transfer -> storage; Move Medium DT2MT [0x07:0:1 ] Data transfer -> medium transport; Move Medium MT_WA [0x0c:7:2 ] Medium transport elements support Write Attribute MTEDT [0x0c:3:1 ] Medium transport -> data transfer; Exchange Medium MTEIE [0x0c:2:1 ] Medium transport -> import/export; Exchange Medium MTEST [0x0c:1:1 ] Medium transport -> storage; Exchange Medium MTEMT [0x0c:0:1 ] Medium transport -> medium transport; Exchange Medium ST_WA [0x0d:7:2 ] Storage elements support Write Attribute STEDT [0x0d:3:1 ] Storage -> data transfer; Exchange Medium STEIE [0x0d:2:1 ] Storage -> import/export; Exchange Medium STEST [0x0d:1:1 ] Storage -> storage; Exchange Medium STEMT [0x0d:0:1 ] Storage -> medium transport; Exchange Medium IE_WA [0x0e:7:2 ] Import/export elements support Write Attribute IEEDT [0x0e:3:1 ] Import/export -> data transfer; Exchange Medium IEEIE [0x0e:2:1 ] Import/export -> import/export; Exchange Medium IEEST [0x0e:1:1 ] Import/export -> storage; Exchange Medium IEEMT [0x0e:0:1 ] Import/export -> medium transport; Exchange Medium DT_WA [0x0f:7:2 ] Data transfer elements support Write Attribute DTEDT [0x0f:3:1 ] Data transfer -> data transfer; Exchange Medium DTEIE [0x0f:2:1 ] Data transfer -> import/export; Exchange Medium DTEST [0x0f:1:1 ] Data transfer -> storage; Exchange Medium DTEMT [0x0f:0:1 ] Data transfer -> medium transport; Exchange Medium Extended device capabilities (SMC) [edc: 0x1f,0x41] [medium changer] mode page: MVPRV [0x04:5:1 ] Move prevented to import/export element MVCL [0x04:4:1 ] Move closes import/export element MVOP [0x04:3:1 ] Move opens import/export element USRCL [0x04:2:1 ] User control import/export element close USROP [0x04:1:1 ] User control import/export element open IEST [0x04:0:1 ] Import/export element state DTETA [0x05:4:1 ] Data transfer element empty on door access RSSEA [0x05:3:1 ] Return to source storage element address MVTRY [0x05:2:1 ] Move tray IEMGZ [0x05:1:1 ] Import/export magazine SMGZ [0x05:0:1 ] Storage magazine TREXC [0x06:2:1 ] True exchange capable LCKIE [0x06:1:1 ] Lock import/export element LCKD [0x06:0:1 ] Lock door SPMER [0x07:2:1 ] Source pre-move eject required DPMER [0x07:1:1 ] Destination pre-move eject required PEPOS [0x07:0:1 ] Pre-eject position UCST [0x08:0:1 ] Unassigned cleaning storage CD/DVD (MM) capabilities and mechanical status (MMC) [cms: 0x2a] [cd/dvd] mode page: D_RAM_R [0x02:5:1 ] DVD-RAM read D_R_R [0x02:4:1 ] DVD-R read D_ROM_R [0x02:3:1 ] DVD-ROM read METH2 [0x02:2:1 ] Method 2 CD_RW_R [0x02:1:1 ] CD-RW read CD_R_R [0x02:0:1 ] CD-R read D_RAM_W [0x03:5:1 ] DVD-RAM write D_R_W [0x03:4:1 ] DVD-R write TST_WR [0x03:2:1 ] Test write CD_RW_W [0x03:1:1 ] CD-RW write CD_R_W [0x03:0:1 ] CD-R write BUF [0x04:7:1 ] Buffer underrun free recording MULT_S [0x04:6:1 ] Multi session M2F2 [0x04:5:1 ] Mode 2 form 2 M2F1 [0x04:4:1 ] Mode 2 form 1 DP_2 [0x04:3:1 ] Digital port 2 DP_1 [0x04:2:1 ] Digital port 1 COMP [0x04:1:1 ] Composite AUDIO_P [0x04:0:1 ] Audio play RBC [0x05:7:1 ] Read bar code UPC [0x05:6:1 ] Uniform product code ISRC [0x05:5:1 ] International standard recording code C2PS [0x05:4:1 ] C 2 pointers supported RW_DC [0x05:3:1 ] R-W de-interleaved and corrected RW_S [0x05:2:1 ] R-W supported CDDA_SA [0x05:1:1 ] CD-DA stream accurate CDDA_CS [0x05:0:1 ] CD-DA commands supported LMT [0x06:7:3 ] Loading mechanism type EJECT [0x06:3:1 ] Eject (individual or magazine) PJ [0x06:2:1 ] Prevent jumper LS [0x06:1:1 ] Lock state LOCK [0x06:0:1 ] Lock (supported) RWILI [0x07:5:1 ] R-W in lead in SCC [0x07:4:1 ] Side change capable SSS [0x07:3:1 ] Software slot selection CSDP [0x07:2:1 ] Changer supports disc present SCM [0x07:1:1 ] Separate channel mute SVL [0x07:0:1 ] Separate volume levels MRSS [0x08:7:16] Maximum read speed supported (kBps) (obs) NVLS [0x0a:7:16] Number of volume levels supported BSS [0x0c:7:16] Buffer size supported (1024 bytes) LENGTH [0x11:5:2 ] Length (bit length of IEC958 words) LSBF [0x11:3:1 ] LSB (least significant bit) first RCK [0x11:2:1 ] High on LRCK indicates left channel BCKF [0x11:1:1 ] BCK signal falling edge CMRS [0x16:7:16] Copy management revision supported RCS [0x1b:1:2 ] Rotation control selected CWSS [0x1c:7:16] Current write speed selected Mode pages for Fibre Channel Protocol for SCSI (FCP-5) transport protocol: Disconnect-reconnect (FCP) [dr: 0x2] mode page: BFR [0x02:7:8 ] Buffer full ratio BER [0x03:7:8 ] Buffer empty ratio BIL [0x04:7:16] Bus inactivity limit (transmission words) DTL [0x06:7:16] Disconnect time limit (128 transmission words) CTL [0x08:7:16] Connect time limit (128 transmission words) MBS [0x0a:7:16] Maximum burst size (512 bytes) EMDP [0x0c:7:1 ] Enable modify data pointers FAA [0x0c:6:1 ] Fairness access A [FCP_DATA] FAB [0x0c:5:1 ] Fairness access B [FCP_XFER] FAC [0x0c:4:1 ] Fairness access C [FCP_RSP] FBS [0x0e:7:16] First burst size (512 bytes) lu: control (FCP) [luc: 0x18] mode page: LUPID [0x02:3:4 ] Logical unit's (transport) protocol identifier EPDC [0x03:0:1 ] Enable precise delivery checking port: control (FCP) [pc: 0x19] mode page: PPID [0x02:3:4 ] Port's (transport) protocol identifier DTFD [0x03:7:1 ] Disable target fabric discovery PLPB [0x03:6:1 ] Prevent loop port bypass DDIS [0x03:5:1 ] Disable discovery DLM [0x03:4:1 ] Disable loop master RHA [0x03:3:1 ] Require hard address ALWI [0x03:2:1 ] Allow login without loop initialization DTIPE [0x03:1:1 ] Disable target initialized port enable DTOLI [0x03:0:1 ] Disable target originated loop initialization RRTVU [0x06:2:3 ] Resource recovery timeout value unit RR_TOV [0x06:2:3 ] Resource recovery timeout value unit SIRRTV [0x07:7:8 ] Sequence initiative resource recovery timeout value Mode pages for SCSI Parallel Interface (SPI-5) transport protocol: Disconnect-reconnect (SPI) [dr: 0x2] mode page: BFR [0x02:7:8 ] Buffer full ratio BER [0x03:7:8 ] Buffer empty ratio BIL [0x04:7:16] Bus inactivity limit (100 us) PDTL [0x06:7:16] Physical disconnect time limit (100 us) CTL [0x08:7:16] Connect time limit (100 us) MBS [0x0a:7:16] Maximum burst size (512 bytes) EMDP [0x0c:7:1 ] Enable modify data pointers FA [0x0c:6:3 ] Fair arbitration DIMM [0x0c:3:1 ] Disconnect immediate DTDC [0x0c:2:3 ] Data transfer disconnect control lu: control (SPI) [luc: 0x18] mode page: LUPID [0x02:3:4 ] Logical unit's (transport) protocol identifier port: short format (SPI) [psf: 0x19] mode page: PPID [0x02:3:4 ] Port's (transport) protocol identifier STT [0x04:7:16] Synchronous transfer timeout (ms) port: margin control (SPI) [mc: 0x19,0x1] mode page: PPID_1 [0x05:3:4 ] Port's (transport) protocol identifier DS [0x07:7:4 ] Driver strength DA [0x08:7:4 ] Driver asymmetry DP [0x08:3:4 ] Driver precompensation DSR [0x09:7:4 ] Driver slew rate port: saved training config value (SPI) [stc: 0x19,0x2] mode page: PPID_2 [0x05:3:4 ] Port's (transport) protocol identifier DB0 [0x0a:7:32] DB(0) value DB1 [0x0e:7:32] DB(1) value DB2 [0x12:7:32] DB(2) value DB3 [0x16:7:32] DB(3) value DB4 [0x1a:7:32] DB(4) value DB5 [0x1e:7:32] DB(5) value DB6 [0x22:7:32] DB(6) value DB7 [0x26:7:32] DB(7) value DB8 [0x2a:7:32] DB(8) value DB9 [0x2e:7:32] DB(9) value DB10 [0x32:7:32] DB(10) value DB11 [0x36:7:32] DB(11) value DB12 [0x3a:7:32] DB(12) value DB13 [0x3e:7:32] DB(13) value DB14 [0x42:7:32] DB(14) value DB15 [0x46:7:32] DB(15) value P_CRCA [0x4a:7:32] P_CRCA value P1 [0x4e:7:32] P1 value BSY [0x52:7:32] BSY value SEL [0x56:7:32] SEL value RST [0x5a:7:32] RST value REQ [0x5e:7:32] REQ value ACK [0x62:7:32] ACK value ATN [0x66:7:32] ATN value C_D [0x6a:7:32] C/D value I_O [0x6e:7:32] I/O value MSG [0x72:7:32] MSG value port: negotiated settings (SPI) [ns: 0x19,0x3] mode page: PPID_3 [0x05:3:4 ] Port's (transport) protocol identifier TPF [0x06:7:8 ] Transfer period factor RAO [0x08:7:8 ] REQ/ACK offset TWE [0x09:7:8 ] Transfer width exponent POB [0x0a:6:7 ] Protocol option bits TM [0x0b:3:2 ] Transceiver mode SPE [0x0b:1:1 ] Sent PCOMP_EN bit (for current I_T nexus) RPE [0x0b:0:1 ] Received PCOMP_EN bit (for current I_T nexus) port: report transfer capabilities (SPI) [rtc: 0x19,0x4] mode page: PPID_4 [0x05:3:4 ] Port's (transport) protocol identifier MTPF [0x06:7:8 ] Minimum transfer period factor MRAO [0x08:7:8 ] Maximum REQ/ACK offset MTWE [0x09:7:8 ] Maximum transfer width exponent POBS [0x0a:7:8 ] Protocol option bits supported Mode pages for Serial Storage Architecture SCSI-3 Protocol (SSA-S3P) transport protocol: Mode pages for Serial Bus Protocol for IEEE 1394 (SBP-3) transport protocol: Mode pages for SCSI RDMA Protocol (SRP) transport protocol: Disconnect-reconnect (SRP) [dr: 0x2] mode page: MBS [0x0a:7:16] Maximum burst size (512 bytes) EMDP [0x0c:7:1 ] Enable modify data pointers FBS [0x0e:7:16] First burst size (512 bytes) Mode pages for Internet SCSI (iSCSI) transport protocol: Mode pages for Serial Attached SCSI Protocol (SPL-4) transport protocol: Disconnect-reconnect (SAS) [dr: 0x2] mode page: BITL [0x04:7:16] Bus inactivity (time) limit (100us or see BILUNIT) MCTL [0x08:7:16] Connect time limit (100us or see CTLUNIT) MBS [0x0a:7:16] Maximum burst size (512 bytes) CTLUNIT [0x0d:3:2 ] Connect time limit unit BILUNIT [0x0d:1:2 ] Bus inactivity (time) limit unit FBS [0x0e:7:16] First burst size (512 bytes) Protocol specific logical unit (SAS) [pl: 0x18] mode page: LUPID [0x02:3:4 ] Logical unit's (transport) protocol identifier TLR [0x02:4:1 ] Transport layer retries Protocol specific port (SAS) [pp: 0x19] mode page: PPID [0x02:3:4 ] Port's (transport) protocol identifier CAWT [0x02:6:1 ] Continue AWT (arbitration wait time (timer)) BAE [0x02:5:1 ] Broadcast asynchronous event RLM [0x02:4:1 ] Ready LED meaning ITNLT [0x04:7:16] I_T nexus loss time (ms) IRT [0x06:7:16] Initiator response timeout (ms) RTOL [0x08:7:16] Reject to open limit (10 us) MAXR [0x0a:7:8 ] Maximum allowed xfer ready Phy control and discover (SAS) [pcd: 0x19,0x1] mode page: PPID_1 [0x05:3:4 ] Port's (transport) protocol identifier GENC [0x06:7:8 ] Generation code NOP [0x07:7:8 ] Number of phys PHID [0x09:7:8 ] Phy identifier ADT [0x0c:6:3 ] Attached SAS device type AREAS [0x0c:3:4 ] Attached reason (other end did link reset) REAS [0x0d:7:4 ] Reason (for starting link reset) NLLR [0x0d:3:4 ] Negotiated logical link rate ASIP [0x0e:3:1 ] Attached SSP initiator port ATIP [0x0e:2:1 ] Attached STP initiator port AMIP [0x0e:1:1 ] Attached SMP initiator port ASTP [0x0f:3:1 ] Attached SSP target port ATTP [0x0f:2:1 ] Attached STP target port AMTP [0x0f:1:1 ] Attached SMP target port SASA [0x10:7:64] SAS address ASASA [0x18:7:64] Attached SAS address APHID [0x20:7:8 ] Attached phy identifier APERCAP [0x21:7:1 ] Attached persistent capable APOWCAP [0x21:6:2 ] Attached power capable ASLCAP [0x21:4:1 ] Attached slumber capable APACAP [0x21:3:1 ] Attached partial capable AIZPER [0x21:2:1 ] Attached inside ZPSDS persistent AREQIZ [0x21:1:1 ] Attached requested inside ZPSDS ABRCAP [0x21:0:1 ] Attached break reply capable AAPTACAP [0x22:2:1 ] Attached APTA capable ASMPPCAP [0x22:1:1 ] Attached SMP priority capable APOWDCAP [0x22:0:1 ] Attached power disable capable PMILR [0x28:7:4 ] Programmed minimum link rate HMILR [0x28:3:4 ] Hardware minimum link rate PMALR [0x29:7:4 ] Programmed maximum link rate HMALR [0x29:3:4 ] Hardware maximum link rate Shared port control (SAS) [spc: 0x19,0x2] mode page: PPID_2 [0x05:3:4 ] Port's (transport) protocol identifier PLT [0x06:7:16] Power loss timeout(ms) PGRATO [0x09:7:8 ] Power grant timeout(sec) 4PHYS [0x0a:2:1 ] 4 phy wide port(s) when set 2PHYS [0x0a:1:1 ] 2 phy wide port(s) when set 1PHY [0x0a:0:1 ] single phy (narrow) ports PMCDT [0x0b:7:8 ] port mode change delay time (unit: seconds) Enhanced phy control (SAS) [sep: 0x19,0x3] mode page: PPID_3 [0x05:3:4 ] Port's (transport) protocol identifier GENC_1 [0x06:7:8 ] Generation code NOP_1 [0x07:7:8 ] Number of phys PHID_1 [0x09:7:8 ] Phy identifier PPCAP [0x0c:7:32] Programmed phy capabilities CPCAP [0x10:7:32] Current phy capabilities APCAP [0x14:7:32] Attached phy capabilities OPT_M_EN [0x1a:5:1 ] Optical mode enabled N_SSC [0x1a:4:1 ] Negotiated spread spectrum clocking NPLR [0x1a:3:4 ] Negotiated physical link rate EN_SL [0x1b:2:1 ] Enable slumber phy power condition EN_PA [0x1b:1:1 ] Enable partial phy power condition HMS [0x1b:0:1 ] Hardware muxing supported Out of band management control (SAS) [oobm: 0x19,0x4] mode page: OOB_RE [0x04:7:1 ] Out of band reporting enabled OOB_PRV [0x06:7:16] Out of band protocol revision code OOB_D_ID [0x08:3:4 ] Out of band descriptor identifier TA_TRE [0x0c:0:1 0] Temperature attribute, temperature reporting enabled TA_RI [0x0d:7:8 0] Temperature attribute, reporting interval (seconds) TA_MRI [0x0e:7:8 0] Temperature attribute, minimum reporting interval (seconds) TA_C_UP [0x0f:7:4 0] Temperature attribute, change up (Celsius) TA_C_DO [0x0f:3:4 0] Temperature attribute, change down (Celsius) TA_TM [0x10:1:2 0] Temperature attribute, test mode TA_TM_T [0x12:7:8 0] Temperature attribute test mode temperature Mode pages for Automation/Drive Interface Transport (ADT-2) transport protocol: Mode pages for AT Attachment Interface (ACS-2) transport protocol: Mode pages for USB Attached SCSI (UAS-2) transport protocol: Mode pages for SCSI over PCI Express (SOP) transport protocol: Mode pages for PCIe transport protocol: Mode pages for Oxc transport protocol: Mode pages for Oxd transport protocol: Mode pages for Oxe transport protocol: Mode pages for Seagate disk vendor: Unit attention (seagate) [ua: 0x0] mode page: PM [0x02:7:1 ] Performance Mode SSM [0x02:6:1 ] Synchronous select mode (SPI) IL [0x02:5:1 ] Inquiry length UA [0x02:4:1 ] Unit attention DFUA [0x02:3:1 ] Disable force unit access (FUA) ROUND [0x02:2:1 ] Reporting of log parameter rounding (wrap around) STRICT [0x02:1:1 ] Strict when trying to alter unchangeable mode page fields SCSI2 [0x02:0:1 ] SCSI-2 lengths for control and caching mode pages DAR [0x03:7:1 ] Deferred auto reallocation SSEEK [0x03:6:1 ] Self seek VJIT_DIS [0x04:7:1 ] VJIT disabled JIT3 [0x04:3:1 ] Just in time 3, slowest seek type JIT2 [0x04:2:1 ] Just in time 2, second slowest seek type JIT1 [0x04:1:1 ] Just in time 1, second fastest seek type JIT0 [0x04:0:1 ] Just in time 0, fastest seek type TTE [0x06:0:1 ] Thermal throttle enable (SSD) Mode pages for Hitachi disk vendor: Vendor unique parameters (hitachi) [vup: 0x0] mode page: MRG [0x02:3:1 ] Merge Glist into Plist (during format) VGMDE [0x03:6:1 ] Veggie mode (do random seeks when idle) RRNDE [0x03:1:1 ] Report recovered non data errors (when PER set) DNS [0x04:2:1 ] Disable notify for standby LRPMS [0x04:1:1 ] Low RPM standby LCS [0x04:0:1 ] Limited current startup FDD [0x05:4:1 ] Format degraded disable (reporting for Test Unit Ready) CAEN [0x05:1:1 ] Command aging enable IGRA [0x06:7:1 ] Ignore reassigned LBA (when RC also set) AVERP [0x06:6:1 ] AV ERP mode (maximum retry count for read errors) OCT [0x06:3:12] Overall command timer, 0 -> disabled (50 ms) TT [0x09:7:8 ] Temperature threshold (celsius), 0 -> 85C CAL [0x0a:7:16] Command aging limit (50 ms) RRT [0x0c:7:8 ] Read reporting threshold for read recovered errors when PER set WRT [0x0d:7:8 ] Write reporting threshold for write recovered errors when PER set DRRT [0x0e:7:1 ] Disable restore reassign target FFMT [0x0e:3:1 ] Fast format enable, format without writes to customer media FCERT [0x0f:5:1 ] Format certification (enable) Mode pages for Maxtor disk vendor: Unit attention condition (maxtor) [uac: 0x0] mode page: DUA [0x02:4:1 ] Disable unit attention Mode pages for Fujitsu disk vendor: Additional error recovery parameters (fujitsu) [aerp: 0x21] mode page: RDSE [0x02:3:4 ] Retries during a seek error Mode pages for LTO-5 tape drive (IBM, HP) vendor: Vendor specific (LTO-5) [l5vs: 0x24] mode page: ENCR_E [0x07:3:1 ] Encryption enable FIPS [0x07:1:1 ] FIPS level of code ENCR_C [0x07:0:1 ] Encryption capable Behaviour configuration (LTO-5) [l5bc: 0x2f] mode page: FE_BEH [0x02:7:8 ] Fence behaviour CL_BEH [0x03:7:8 ] Clean behaviour WO_BEH [0x04:7:8 ] Worm behaviour SD_BEH [0x05:7:8 ] Sense data behaviour CCDM [0x06:2:1 ] Check condition for dead media DDEOR [0x06:1:1 ] Disable deferred error on rewind CLNCHK [0x06:0:1 ] Clean check DFMRDL [0x07:0:1 ] Disable field microcode replacement down level UOE_C [0x08:5:2 ] Unload on error - cleaner UOE_F [0x08:3:2 ] Unload on error - FMR UOE_D [0x08:1:2 ] Unload on error - data TA10 [0x09:0:1 ] Tape alert 10h Serial number override (LTO-5) [l5sno: 0x3b] mode page: MSN [0x02:1:2 ] Non-auto SN0_7 [0x06:7:64] Serial Number, bytes 0 to 7 SN8_11 [0x0e:7:32] Serial Number, bytes 8 to 11 Device time (LTO-5) [l5dt: 0x3c] mode page: LT_VAL [0x02:2:1 ] Library time valid WT_VAL [0x02:1:1 ] World time valid PT_VAL [0x02:0:1 ] Power-on time valid CP_COUNT [0x06:7:16] Current power-on count UTC [0x0e:1:1 ] UTC NTP [0x0e:0:1 ] NTP WOR_TIME [0x10:7:32] World time LT_HR [0x17:7:8 ] Library time (hours) LT_MIN [0x18:7:8 ] Library time (minutes) LT_SEC [0x19:7:8 ] Library time (seconds) CUM_PT [0x20:7:32] Cumulative power-on time (seconds) Extended reset (LTO-5) [l5er: 0x3d] mode page: RES_BEH [0x02:1:2 ] Reset behaviour cd-rom emulation / disaster recovery (LTO-5) [l5cde: 0x3e] mode page: NON_AUTO [0x02:1:1 ] Non-auto CD_MODE [0x02:0:1 ] CDmode Mode pages for LTO-6 tape drive (IBM, HP) vendor: Serial number override (LTO-5) [l6sno: 0x3b] mode page: MSN [0x02:1:2 ] Non-auto SN0_7 [0x06:7:64] Serial Number, bytes 0 to 7 SN8_11 [0x0e:7:32] Serial Number, bytes 8 to 11 Device time (LTO-5) [l6dt: 0x3c] mode page: LT_VAL [0x02:2:1 ] Library time valid WT_VAL [0x02:1:1 ] World time valid PT_VAL [0x02:0:1 ] Current power-on count CP_COUNT [0x06:7:16] Power-on time (seconds) UTC [0x0e:1:1 ] UTC NTP [0x0e:0:1 ] NTP WOR_TIME [0x10:7:32] World time LT_HR [0x17:7:8 ] Library time (hours) LT_MIN [0x18:7:8 ] Library time (minutes) LT_SEC [0x19:7:8 ] Library time (seconds) CUM_PT [0x20:7:32] Cumulative power-on time (seconds) Extended reset (LTO-5) [l6er: 0x3d] mode page: RES_BEH [0x02:1:2 ] Reset behaviour cd-rom emulation / disaster recovery (LTO-5) [l6cde: 0x3e] mode page: NON_AUTO [0x02:1:1 ] Non-auto CD_MODE [0x02:0:1 ] CDmode Mode pages for NVMe, SNTL in library vendor: Unit attention (NVMe) [nvme: 0x0] mode page: ENC_OV [0x02:7:8 ] Enclosure override NVME2 [0x03:7:8 ] Place holder, NVMe 2 Mode pages for sg3_utils package defined vendor: Commands: capacity eject load profile ready sense speed[=new_speed_kbps] start stop sync unlock