brintos

brintos / linux-shallow public Read only

0
0
Text · 1.4 KiB · ee7aeb1 Raw
39 lines · plain
1What:		/sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_factory2Date:		August 20213KernelVersion:	5.164Contact:	Jacopo Mondi <jacopo@jmondi.org>5Description:6		Writing '1' triggers a 'Factory' calibration cycle.7 8What:		/sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_background9Date:		August 202110KernelVersion:	5.1611Contact:	Jacopo Mondi <jacopo@jmondi.org>12Description:13		Writing '1' triggers a 'Background' calibration cycle.14 15What:		/sys/bus/iio/devices/iio:deviceX/error_status_available16Date:		August 202117KernelVersion:	5.1618Contact:	Jacopo Mondi <jacopo@jmondi.org>19Description:20		Reading returns the list of possible chip error status.21		Available options are:22		- 'error_fatal': Analog front-end initialization error23		- 'error_i2c': Read/write to non-existing register24		- 'error_algorithm': Corrupted parameters25		- 'error_calibration': Calibration has failed26		- 'error_self_diagnostic': Internal interface failure27		- 'error_out_of_range': Measured concentration out of scale28		- 'error_memory': Error during memory operations29		- 'error_no_measurement': Cleared at first measurement30		- 'error_low_voltage': Sensor regulated voltage too low31		- 'error_measurement_timeout': Unable to complete measurement32 33What:		/sys/bus/iio/devices/iio:deviceX/error_status34Date:		August 202135KernelVersion:	5.1636Contact:	Jacopo Mondi <jacopo@jmondi.org>37Description:38		Reading returns the current chip error status.39