30 lines · plain
1What: /sys/bus/iio/devices/iio:deviceX/in_proximity<id>_setup2Date: November 20213KernelVersion: 5.174Contact: Gwendal Grignou <gwendal@chromium.org>5Description:6 SX9324 has 3 inputs, CS0, CS1 and CS2. Hardware layout7 defines if the input is8 9 + not connected (HZ),10 + grounded (GD),11 + connected to an antenna where it can act as a base12 (DS - data shield), or measured input (MI).13 14 The sensor rotates measurement across 4 phases15 (PH0, PH1, PH2, PH3), where the inputs are configured16 and then measured.17 18 By default, during the first phase, [PH0], CS0 is measured,19 while CS1 and CS2 are used as shields.20 `cat in_proximity0_setup` returns "MI,DS,DS".21 [PH1], CS1 is measured, CS0 and CS2 are shield:22 `cat in_proximity1_setup` returns "DS,MI,DS".23 [PH2], CS2 is measured, CS0 and CS1 are shield:24 `cat in_proximity1_setup` returns "DS,DS,MI".25 [PH3], CS1 and CS2 are measured (combo mode):26 `cat in_proximity1_setup` returns "DS,MI,MI".27 28 Note, these are the chip default. Hardware layout will most29 likely dictate different output. The entry is read-only.30