brintos

brintos / linux-shallow public Read only

0
0
Text · 1.0 KiB · be51a15 Raw
40 lines · plain
1-------------------------------2BCM590xx Power Management Units3-------------------------------4 5Required properties:6- compatible: "brcm,bcm59056"7- reg: I2C slave address8- interrupts: interrupt for the PMU. Generic interrupt client node bindings9  are described in interrupt-controller/interrupts.txt10 11------------------12Voltage Regulators13------------------14 15Optional child nodes:16- regulators: container node for regulators following the generic17  regulator binding in regulator/regulator.txt18 19  The valid regulator node names for BCM59056 are:20  	rfldo, camldo1, camldo2, simldo1, simldo2, sdldo, sdxldo,21	mmcldo1, mmcldo2, audldo, micldo, usbldo, vibldo,22	csr, iosr1, iosr2, msr, sdsr1, sdsr2, vsr,23	gpldo1, gpldo2, gpldo3, gpldo4, gpldo5, gpldo6,24	vbus25 26Example:27	pmu: bcm59056@8 {28		compatible = "brcm,bcm59056";29		reg = <0x08>;30		interrupts = <GIC_SPI 215 IRQ_TYPE_LEVEL_HIGH>;31		regulators {32			rfldo_reg: rfldo {33				regulator-min-microvolt = <1200000>;34				regulator-max-microvolt = <3300000>;35			};36 37			...38		};39	};40