24 lines · plain
1* Holt HI-311X stand-alone CAN controller device tree bindings2 3Required properties:4 - compatible: Should be one of the following:5 - "holt,hi3110" for HI-31106 - reg: SPI chip select.7 - clocks: The clock feeding the CAN controller.8 - interrupts: Should contain IRQ line for the CAN controller.9 10Optional properties:11 - vdd-supply: Regulator that powers the CAN controller.12 - xceiver-supply: Regulator that powers the CAN transceiver.13 14Example:15 can0: can@1 {16 compatible = "holt,hi3110";17 reg = <1>;18 clocks = <&clk32m>;19 interrupt-parent = <&gpio4>;20 interrupts = <13 IRQ_TYPE_LEVEL_HIGH>;21 vdd-supply = <®5v0>;22 xceiver-supply = <®5v0>;23 };24