brintos

brintos / linux-shallow public Read only

0
0
Text · 663 B · 3a9926f Raw
24 lines · plain
1* Holt HI-311X stand-alone CAN controller device tree bindings2 3Required properties:4 - compatible: Should be one of the following:5   - "holt,hi3110" for HI-31106 - reg: SPI chip select.7 - clocks: The clock feeding the CAN controller.8 - interrupts: Should contain IRQ line for the CAN controller.9 10Optional properties:11 - vdd-supply: Regulator that powers the CAN controller.12 - xceiver-supply: Regulator that powers the CAN transceiver.13 14Example:15	can0: can@1 {16		compatible = "holt,hi3110";17		reg = <1>;18		clocks = <&clk32m>;19		interrupt-parent = <&gpio4>;20		interrupts = <13 IRQ_TYPE_LEVEL_HIGH>;21		vdd-supply = <&reg5v0>;22		xceiver-supply = <&reg5v0>;23	};24