brintos

brintos / linux-shallow public Read only

0
0
Text · 4.4 KiB · b9022f1 Raw
123 lines · yaml
1# SPDX-License-Identifier: (GPL-2.0)2# Copyright 2020 Linaro Ltd.3%YAML 1.24---5$id: http://devicetree.org/schemas/thermal/thermal-cooling-devices.yaml#6$schema: http://devicetree.org/meta-schemas/core.yaml#7 8title: Thermal cooling device9 10maintainers:11  - Amit Kucheria <amitk@kernel.org>12 13description: |14  Thermal management is achieved in devicetree by describing the sensor hardware15  and the software abstraction of cooling devices and thermal zones required to16  take appropriate action to mitigate thermal overload.17 18  The following node types are used to completely describe a thermal management19  system in devicetree:20   - thermal-sensor: device that measures temperature, has SoC-specific bindings21   - cooling-device: device used to dissipate heat either passively or actively22   - thermal-zones: a container of the following node types used to describe all23     thermal data for the platform24 25  This binding describes the cooling devices.26 27  There are essentially two ways to provide control on power dissipation:28    - Passive cooling: by means of regulating device performance. A typical29      passive cooling mechanism is a CPU that has dynamic voltage and frequency30      scaling (DVFS), and uses lower frequencies as cooling states.31    - Active cooling: by means of activating devices in order to remove the32      dissipated heat, e.g. regulating fan speeds.33 34  Any cooling device has a range of cooling states (i.e. different levels of35  heat dissipation). They also have a way to determine the state of cooling in36  which the device is. For example, a fan's cooling states correspond to the37  different fan speeds possible. Cooling states are referred to by single38  unsigned integers, where larger numbers mean greater heat dissipation. The39  precise set of cooling states associated with a device should be defined in40  a particular device's binding.41 42select: true43 44properties:45  "#cooling-cells":46    description:47      Must be 2, in order to specify minimum and maximum cooling state used in48      the cooling-maps reference. The first cell is the minimum cooling state49      and the second cell is the maximum cooling state requested.50    const: 251 52additionalProperties: true53 54examples:55  - |56    #include <dt-bindings/interrupt-controller/arm-gic.h>57    #include <dt-bindings/thermal/thermal.h>58 59    // Example 1: Cpufreq cooling device on CPU060    cpus {61            #address-cells = <2>;62            #size-cells = <0>;63 64            CPU0: cpu@0 {65                    device_type = "cpu";66                    compatible = "qcom,kryo385";67                    reg = <0x0 0x0>;68                    enable-method = "psci";69                    cpu-idle-states = <&LITTLE_CPU_SLEEP_0>,70                                      <&LITTLE_CPU_SLEEP_1>,71                                      <&CLUSTER_SLEEP_0>;72                    capacity-dmips-mhz = <607>;73                    dynamic-power-coefficient = <100>;74                    qcom,freq-domain = <&cpufreq_hw 0>;75                    #cooling-cells = <2>;76                    next-level-cache = <&L2_0>;77                    L2_0: l2-cache {78                            compatible = "cache";79                            cache-unified;80                            cache-level = <2>;81                            next-level-cache = <&L3_0>;82                            L3_0: l3-cache {83                                    compatible = "cache";84                                    cache-unified;85                                    cache-level = <3>;86                            };87                    };88          };89 90          /* ... */91 92    };93 94    /* ... */95 96    thermal-zones {97            cpu0-thermal {98                    polling-delay-passive = <250>;99                    polling-delay = <1000>;100 101                    thermal-sensors = <&tsens0 1>;102 103                    trips {104                            cpu0_alert0: trip-point0 {105                                    temperature = <90000>;106                                    hysteresis = <2000>;107                                    type = "passive";108                            };109                    };110 111                    cooling-maps {112                            map0 {113                                    trip = <&cpu0_alert0>;114                                    /* Corresponds to 1000MHz in OPP table */115                                    cooling-device = <&CPU0 5 5>;116                            };117                    };118            };119 120            /* ... */121    };122...123