brintos

brintos / linux-shallow public Read only

0
0
Text · 10.0 KiB · 980bb3a Raw
483 lines · c
1// SPDX-License-Identifier: GPL-2.0+2/*3 * Interface for Dynamic Logical Partitioning of I/O Slots on4 * RPA-compliant PPC64 platform.5 *6 * John Rose <johnrose@austin.ibm.com>7 * Linda Xie <lxie@us.ibm.com>8 *9 * October 200310 *11 * Copyright (C) 2003 IBM.12 */13 14#undef DEBUG15 16#include <linux/init.h>17#include <linux/module.h>18#include <linux/of.h>19#include <linux/pci.h>20#include <linux/string.h>21#include <linux/vmalloc.h>22 23#include <asm/pci-bridge.h>24#include <linux/mutex.h>25#include <asm/rtas.h>26#include <asm/vio.h>27#include <linux/firmware.h>28 29#include "../pci.h"30#include "rpaphp.h"31#include "rpadlpar.h"32 33static DEFINE_MUTEX(rpadlpar_mutex);34 35#define DLPAR_MODULE_NAME "rpadlpar_io"36 37#define NODE_TYPE_VIO  138#define NODE_TYPE_SLOT 239#define NODE_TYPE_PHB  340 41static struct device_node *find_vio_slot_node(char *drc_name)42{43	struct device_node *parent = of_find_node_by_name(NULL, "vdevice");44	struct device_node *dn;45	int rc;46 47	if (!parent)48		return NULL;49 50	for_each_child_of_node(parent, dn) {51		rc = rpaphp_check_drc_props(dn, drc_name, NULL);52		if (rc == 0)53			break;54	}55	of_node_put(parent);56 57	return dn;58}59 60/* Find dlpar-capable pci node that contains the specified name and type */61static struct device_node *find_php_slot_pci_node(char *drc_name,62						  char *drc_type)63{64	struct device_node *np;65	int rc;66 67	for_each_node_by_name(np, "pci") {68		rc = rpaphp_check_drc_props(np, drc_name, drc_type);69		if (rc == 0)70			break;71	}72 73	return np;74}75 76/* Returns a device_node with its reference count incremented */77static struct device_node *find_dlpar_node(char *drc_name, int *node_type)78{79	struct device_node *dn;80 81	dn = find_php_slot_pci_node(drc_name, "SLOT");82	if (dn) {83		*node_type = NODE_TYPE_SLOT;84		return dn;85	}86 87	dn = find_php_slot_pci_node(drc_name, "PHB");88	if (dn) {89		*node_type = NODE_TYPE_PHB;90		return dn;91	}92 93	dn = find_vio_slot_node(drc_name);94	if (dn) {95		*node_type = NODE_TYPE_VIO;96		return dn;97	}98 99	return NULL;100}101 102/**103 * find_php_slot - return hotplug slot structure for device node104 * @dn: target &device_node105 *106 * This routine will return the hotplug slot structure107 * for a given device node. Note that built-in PCI slots108 * may be dlpar-able, but not hot-pluggable, so this routine109 * will return NULL for built-in PCI slots.110 */111static struct slot *find_php_slot(struct device_node *dn)112{113	struct slot *slot, *next;114 115	list_for_each_entry_safe(slot, next, &rpaphp_slot_head,116				 rpaphp_slot_list) {117		if (slot->dn == dn)118			return slot;119	}120 121	return NULL;122}123 124static struct pci_dev *dlpar_find_new_dev(struct pci_bus *parent,125					struct device_node *dev_dn)126{127	struct pci_dev *tmp = NULL;128	struct device_node *child_dn;129 130	list_for_each_entry(tmp, &parent->devices, bus_list) {131		child_dn = pci_device_to_OF_node(tmp);132		if (child_dn == dev_dn)133			return tmp;134	}135	return NULL;136}137 138static void dlpar_pci_add_bus(struct device_node *dn)139{140	struct pci_dn *pdn = PCI_DN(dn);141	struct pci_controller *phb = pdn->phb;142	struct pci_dev *dev = NULL;143 144	pseries_eeh_init_edev_recursive(pdn);145 146	/* Add EADS device to PHB bus, adding new entry to bus->devices */147	dev = of_create_pci_dev(dn, phb->bus, pdn->devfn);148	if (!dev) {149		printk(KERN_ERR "%s: failed to create pci dev for %pOF\n",150				__func__, dn);151		return;152	}153 154	/* Scan below the new bridge */155	if (pci_is_bridge(dev))156		of_scan_pci_bridge(dev);157 158	/* Map IO space for child bus, which may or may not succeed */159	pcibios_map_io_space(dev->subordinate);160 161	/* Finish adding it : resource allocation, adding devices, etc...162	 * Note that we need to perform the finish pass on the -parent-163	 * bus of the EADS bridge so the bridge device itself gets164	 * properly added165	 */166	pcibios_finish_adding_to_bus(phb->bus);167}168 169static int dlpar_add_pci_slot(char *drc_name, struct device_node *dn)170{171	struct pci_dev *dev;172	struct pci_controller *phb;173 174	if (pci_find_bus_by_node(dn))175		return -EINVAL;176 177	/* Add pci bus */178	dlpar_pci_add_bus(dn);179 180	/* Confirm new bridge dev was created */181	phb = PCI_DN(dn)->phb;182	dev = dlpar_find_new_dev(phb->bus, dn);183 184	if (!dev) {185		printk(KERN_ERR "%s: unable to add bus %s\n", __func__,186			drc_name);187		return -EIO;188	}189 190	if (dev->hdr_type != PCI_HEADER_TYPE_BRIDGE) {191		printk(KERN_ERR "%s: unexpected header type %d, unable to add bus %s\n",192			__func__, dev->hdr_type, drc_name);193		return -EIO;194	}195 196	/* Add hotplug slot */197	if (rpaphp_add_slot(dn)) {198		printk(KERN_ERR "%s: unable to add hotplug slot %s\n",199			__func__, drc_name);200		return -EIO;201	}202	return 0;203}204 205static int dlpar_remove_phb(char *drc_name, struct device_node *dn)206{207	struct slot *slot;208	struct pci_dn *pdn;209	int rc = 0;210 211	if (!pci_find_bus_by_node(dn))212		return -EINVAL;213 214	/* If pci slot is hotpluggable, use hotplug to remove it */215	slot = find_php_slot(dn);216	if (slot && rpaphp_deregister_slot(slot)) {217		printk(KERN_ERR "%s: unable to remove hotplug slot %s\n",218		       __func__, drc_name);219		return -EIO;220	}221 222	pdn = dn->data;223	BUG_ON(!pdn || !pdn->phb);224	rc = remove_phb_dynamic(pdn->phb);225	if (rc < 0)226		return rc;227 228	pdn->phb = NULL;229 230	return 0;231}232 233static int dlpar_add_phb(char *drc_name, struct device_node *dn)234{235	struct pci_controller *phb;236 237	if (PCI_DN(dn) && PCI_DN(dn)->phb) {238		/* PHB already exists */239		return -EINVAL;240	}241 242	phb = init_phb_dynamic(dn);243	if (!phb)244		return -EIO;245 246	if (rpaphp_add_slot(dn)) {247		printk(KERN_ERR "%s: unable to add hotplug slot %s\n",248			__func__, drc_name);249		return -EIO;250	}251	return 0;252}253 254static int dlpar_add_vio_slot(char *drc_name, struct device_node *dn)255{256	struct vio_dev *vio_dev;257 258	vio_dev = vio_find_node(dn);259	if (vio_dev) {260		put_device(&vio_dev->dev);261		return -EINVAL;262	}263 264	if (!vio_register_device_node(dn)) {265		printk(KERN_ERR266			"%s: failed to register vio node %s\n",267			__func__, drc_name);268		return -EIO;269	}270	return 0;271}272 273/**274 * dlpar_add_slot - DLPAR add an I/O Slot275 * @drc_name: drc-name of newly added slot276 *277 * Make the hotplug module and the kernel aware of a newly added I/O Slot.278 * Return Codes:279 * 0			Success280 * -ENODEV		Not a valid drc_name281 * -EINVAL		Slot already added282 * -ERESTARTSYS		Signalled before obtaining lock283 * -EIO			Internal PCI Error284 */285int dlpar_add_slot(char *drc_name)286{287	struct device_node *dn = NULL;288	int node_type;289	int rc = -EIO;290 291	if (mutex_lock_interruptible(&rpadlpar_mutex))292		return -ERESTARTSYS;293 294	/* Find newly added node */295	dn = find_dlpar_node(drc_name, &node_type);296	if (!dn) {297		rc = -ENODEV;298		goto exit;299	}300 301	switch (node_type) {302		case NODE_TYPE_VIO:303			rc = dlpar_add_vio_slot(drc_name, dn);304			break;305		case NODE_TYPE_SLOT:306			rc = dlpar_add_pci_slot(drc_name, dn);307			break;308		case NODE_TYPE_PHB:309			rc = dlpar_add_phb(drc_name, dn);310			break;311	}312	of_node_put(dn);313 314	printk(KERN_INFO "%s: slot %s added\n", DLPAR_MODULE_NAME, drc_name);315exit:316	mutex_unlock(&rpadlpar_mutex);317	return rc;318}319 320/**321 * dlpar_remove_vio_slot - DLPAR remove a virtual I/O Slot322 * @drc_name: drc-name of newly added slot323 * @dn: &device_node324 *325 * Remove the kernel and hotplug representations of an I/O Slot.326 * Return Codes:327 * 0			Success328 * -EINVAL		Vio dev doesn't exist329 */330static int dlpar_remove_vio_slot(char *drc_name, struct device_node *dn)331{332	struct vio_dev *vio_dev;333 334	vio_dev = vio_find_node(dn);335	if (!vio_dev)336		return -EINVAL;337 338	vio_unregister_device(vio_dev);339 340	put_device(&vio_dev->dev);341 342	return 0;343}344 345/**346 * dlpar_remove_pci_slot - DLPAR remove a PCI I/O Slot347 * @drc_name: drc-name of newly added slot348 * @dn: &device_node349 *350 * Remove the kernel and hotplug representations of a PCI I/O Slot.351 * Return Codes:352 * 0			Success353 * -ENODEV		Not a valid drc_name354 * -EIO			Internal PCI Error355 */356static int dlpar_remove_pci_slot(char *drc_name, struct device_node *dn)357{358	struct pci_bus *bus;359	struct slot *slot;360	int ret = 0;361 362	pci_lock_rescan_remove();363 364	bus = pci_find_bus_by_node(dn);365	if (!bus) {366		ret = -EINVAL;367		goto out;368	}369 370	pr_debug("PCI: Removing PCI slot below EADS bridge %s\n",371		 bus->self ? pci_name(bus->self) : "<!PHB!>");372 373	slot = find_php_slot(dn);374	if (slot) {375		pr_debug("PCI: Removing hotplug slot for %04x:%02x...\n",376			 pci_domain_nr(bus), bus->number);377 378		if (rpaphp_deregister_slot(slot)) {379			printk(KERN_ERR380				"%s: unable to remove hotplug slot %s\n",381				__func__, drc_name);382			ret = -EIO;383			goto out;384		}385	}386 387	/* Remove all devices below slot */388	pci_hp_remove_devices(bus);389 390	/* Unmap PCI IO space */391	if (pcibios_unmap_io_space(bus)) {392		printk(KERN_ERR "%s: failed to unmap bus range\n",393			__func__);394		ret = -ERANGE;395		goto out;396	}397 398	/* Remove the EADS bridge device itself */399	BUG_ON(!bus->self);400	pr_debug("PCI: Now removing bridge device %s\n", pci_name(bus->self));401	pci_stop_and_remove_bus_device(bus->self);402 403 out:404	pci_unlock_rescan_remove();405	return ret;406}407 408/**409 * dlpar_remove_slot - DLPAR remove an I/O Slot410 * @drc_name: drc-name of newly added slot411 *412 * Remove the kernel and hotplug representations of an I/O Slot.413 * Return Codes:414 * 0			Success415 * -ENODEV		Not a valid drc_name416 * -EINVAL		Slot already removed417 * -ERESTARTSYS		Signalled before obtaining lock418 * -EIO			Internal Error419 */420int dlpar_remove_slot(char *drc_name)421{422	struct device_node *dn;423	int node_type;424	int rc = 0;425 426	if (mutex_lock_interruptible(&rpadlpar_mutex))427		return -ERESTARTSYS;428 429	dn = find_dlpar_node(drc_name, &node_type);430	if (!dn) {431		rc = -ENODEV;432		goto exit;433	}434 435	switch (node_type) {436		case NODE_TYPE_VIO:437			rc = dlpar_remove_vio_slot(drc_name, dn);438			break;439		case NODE_TYPE_PHB:440			rc = dlpar_remove_phb(drc_name, dn);441			break;442		case NODE_TYPE_SLOT:443			rc = dlpar_remove_pci_slot(drc_name, dn);444			break;445	}446	of_node_put(dn);447	vm_unmap_aliases();448 449	printk(KERN_INFO "%s: slot %s removed\n", DLPAR_MODULE_NAME, drc_name);450exit:451	mutex_unlock(&rpadlpar_mutex);452	return rc;453}454 455static inline int is_dlpar_capable(void)456{457	int rc = rtas_token("ibm,configure-connector");458 459	return (int) (rc != RTAS_UNKNOWN_SERVICE);460}461 462static int __init rpadlpar_io_init(void)463{464 465	if (!is_dlpar_capable()) {466		printk(KERN_WARNING "%s: partition not DLPAR capable\n",467			__func__);468		return -EPERM;469	}470 471	return dlpar_sysfs_init();472}473 474static void __exit rpadlpar_io_exit(void)475{476	dlpar_sysfs_exit();477}478 479module_init(rpadlpar_io_init);480module_exit(rpadlpar_io_exit);481MODULE_LICENSE("GPL");482MODULE_DESCRIPTION("RPA Dynamic Logical Partitioning driver for I/O slots");483