brintos

brintos / linux-shallow public Read only

0
0
Text · 17.4 KiB · 9f60094 Raw
734 lines · c
1// SPDX-License-Identifier: GPL-2.0-only2/*3 * Battery driver for One Laptop Per Child board.4 *5 *	Copyright © 2006-2010  David Woodhouse <dwmw2@infradead.org>6 */7 8#include <linux/kernel.h>9#include <linux/module.h>10#include <linux/mod_devicetable.h>11#include <linux/types.h>12#include <linux/err.h>13#include <linux/device.h>14#include <linux/of.h>15#include <linux/platform_device.h>16#include <linux/power_supply.h>17#include <linux/jiffies.h>18#include <linux/sched.h>19#include <linux/olpc-ec.h>20 21 22#define EC_BAT_VOLTAGE	0x10	/* uint16_t,	*9.76/32,    mV   */23#define EC_BAT_CURRENT	0x11	/* int16_t,	*15.625/120, mA   */24#define EC_BAT_ACR	0x12	/* int16_t,	*6250/15,    µAh  */25#define EC_BAT_TEMP	0x13	/* uint16_t,	*100/256,   °C  */26#define EC_AMB_TEMP	0x14	/* uint16_t,	*100/256,   °C  */27#define EC_BAT_STATUS	0x15	/* uint8_t,	bitmask */28#define EC_BAT_SOC	0x16	/* uint8_t,	percentage */29#define EC_BAT_SERIAL	0x17	/* uint8_t[6] */30#define EC_BAT_EEPROM	0x18	/* uint8_t adr as input, uint8_t output */31#define EC_BAT_ERRCODE	0x1f	/* uint8_t,	bitmask */32 33#define BAT_STAT_PRESENT	0x0134#define BAT_STAT_FULL		0x0235#define BAT_STAT_LOW		0x0436#define BAT_STAT_DESTROY	0x0837#define BAT_STAT_AC		0x1038#define BAT_STAT_CHARGING	0x2039#define BAT_STAT_DISCHARGING	0x4040#define BAT_STAT_TRICKLE	0x8041 42#define BAT_ERR_INFOFAIL	0x0243#define BAT_ERR_OVERVOLTAGE	0x0444#define BAT_ERR_OVERTEMP	0x0545#define BAT_ERR_GAUGESTOP	0x0646#define BAT_ERR_OUT_OF_CONTROL	0x0747#define BAT_ERR_ID_FAIL		0x0948#define BAT_ERR_ACR_FAIL	0x1049 50#define BAT_ADDR_MFR_TYPE	0x5F51 52struct olpc_battery_data {53	struct power_supply *olpc_ac;54	struct power_supply *olpc_bat;55	char bat_serial[17];56	bool new_proto;57	bool little_endian;58};59 60/*********************************************************************61 *		Power62 *********************************************************************/63 64static int olpc_ac_get_prop(struct power_supply *psy,65			    enum power_supply_property psp,66			    union power_supply_propval *val)67{68	int ret = 0;69	uint8_t status;70 71	switch (psp) {72	case POWER_SUPPLY_PROP_ONLINE:73		ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &status, 1);74		if (ret)75			return ret;76 77		val->intval = !!(status & BAT_STAT_AC);78		break;79	default:80		ret = -EINVAL;81		break;82	}83	return ret;84}85 86static enum power_supply_property olpc_ac_props[] = {87	POWER_SUPPLY_PROP_ONLINE,88};89 90static const struct power_supply_desc olpc_ac_desc = {91	.name = "olpc_ac",92	.type = POWER_SUPPLY_TYPE_MAINS,93	.properties = olpc_ac_props,94	.num_properties = ARRAY_SIZE(olpc_ac_props),95	.get_property = olpc_ac_get_prop,96};97 98static int olpc_bat_get_status(struct olpc_battery_data *data,99		union power_supply_propval *val, uint8_t ec_byte)100{101	if (data->new_proto) {102		if (ec_byte & (BAT_STAT_CHARGING | BAT_STAT_TRICKLE))103			val->intval = POWER_SUPPLY_STATUS_CHARGING;104		else if (ec_byte & BAT_STAT_DISCHARGING)105			val->intval = POWER_SUPPLY_STATUS_DISCHARGING;106		else if (ec_byte & BAT_STAT_FULL)107			val->intval = POWER_SUPPLY_STATUS_FULL;108		else /* er,... */109			val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;110	} else {111		/* Older EC didn't report charge/discharge bits */112		if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */113			val->intval = POWER_SUPPLY_STATUS_DISCHARGING;114		else if (ec_byte & BAT_STAT_FULL)115			val->intval = POWER_SUPPLY_STATUS_FULL;116		else /* Not _necessarily_ true but EC doesn't tell all yet */117			val->intval = POWER_SUPPLY_STATUS_CHARGING;118	}119 120	return 0;121}122 123static int olpc_bat_get_health(union power_supply_propval *val)124{125	uint8_t ec_byte;126	int ret;127 128	ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);129	if (ret)130		return ret;131 132	switch (ec_byte) {133	case 0:134		val->intval = POWER_SUPPLY_HEALTH_GOOD;135		break;136 137	case BAT_ERR_OVERTEMP:138		val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;139		break;140 141	case BAT_ERR_OVERVOLTAGE:142		val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;143		break;144 145	case BAT_ERR_INFOFAIL:146	case BAT_ERR_OUT_OF_CONTROL:147	case BAT_ERR_ID_FAIL:148	case BAT_ERR_ACR_FAIL:149		val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;150		break;151 152	default:153		/* Eep. We don't know this failure code */154		ret = -EIO;155	}156 157	return ret;158}159 160static int olpc_bat_get_mfr(union power_supply_propval *val)161{162	uint8_t ec_byte;163	int ret;164 165	ec_byte = BAT_ADDR_MFR_TYPE;166	ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);167	if (ret)168		return ret;169 170	switch (ec_byte >> 4) {171	case 1:172		val->strval = "Gold Peak";173		break;174	case 2:175		val->strval = "BYD";176		break;177	default:178		val->strval = "Unknown";179		break;180	}181 182	return ret;183}184 185static int olpc_bat_get_tech(union power_supply_propval *val)186{187	uint8_t ec_byte;188	int ret;189 190	ec_byte = BAT_ADDR_MFR_TYPE;191	ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);192	if (ret)193		return ret;194 195	switch (ec_byte & 0xf) {196	case 1:197		val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;198		break;199	case 2:200		val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;201		break;202	default:203		val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;204		break;205	}206 207	return ret;208}209 210static int olpc_bat_get_charge_full_design(union power_supply_propval *val)211{212	uint8_t ec_byte;213	union power_supply_propval tech;214	int ret, mfr;215 216	ret = olpc_bat_get_tech(&tech);217	if (ret)218		return ret;219 220	ec_byte = BAT_ADDR_MFR_TYPE;221	ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);222	if (ret)223		return ret;224 225	mfr = ec_byte >> 4;226 227	switch (tech.intval) {228	case POWER_SUPPLY_TECHNOLOGY_NiMH:229		switch (mfr) {230		case 1: /* Gold Peak */231			val->intval = 3000000*.8;232			break;233		default:234			return -EIO;235		}236		break;237 238	case POWER_SUPPLY_TECHNOLOGY_LiFe:239		switch (mfr) {240		case 1: /* Gold Peak, fall through */241		case 2: /* BYD */242			val->intval = 2800000;243			break;244		default:245			return -EIO;246		}247		break;248 249	default:250		return -EIO;251	}252 253	return ret;254}255 256static int olpc_bat_get_charge_now(union power_supply_propval *val)257{258	uint8_t soc;259	union power_supply_propval full;260	int ret;261 262	ret = olpc_ec_cmd(EC_BAT_SOC, NULL, 0, &soc, 1);263	if (ret)264		return ret;265 266	ret = olpc_bat_get_charge_full_design(&full);267	if (ret)268		return ret;269 270	val->intval = soc * (full.intval / 100);271	return 0;272}273 274static int olpc_bat_get_voltage_max_design(union power_supply_propval *val)275{276	uint8_t ec_byte;277	union power_supply_propval tech;278	int mfr;279	int ret;280 281	ret = olpc_bat_get_tech(&tech);282	if (ret)283		return ret;284 285	ec_byte = BAT_ADDR_MFR_TYPE;286	ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);287	if (ret)288		return ret;289 290	mfr = ec_byte >> 4;291 292	switch (tech.intval) {293	case POWER_SUPPLY_TECHNOLOGY_NiMH:294		switch (mfr) {295		case 1: /* Gold Peak */296			val->intval = 6000000;297			break;298		default:299			return -EIO;300		}301		break;302 303	case POWER_SUPPLY_TECHNOLOGY_LiFe:304		switch (mfr) {305		case 1: /* Gold Peak */306			val->intval = 6400000;307			break;308		case 2: /* BYD */309			val->intval = 6500000;310			break;311		default:312			return -EIO;313		}314		break;315 316	default:317		return -EIO;318	}319 320	return ret;321}322 323static u16 ecword_to_cpu(struct olpc_battery_data *data, u16 ec_word)324{325	if (data->little_endian)326		return le16_to_cpu((__force __le16)ec_word);327	else328		return be16_to_cpu((__force __be16)ec_word);329}330 331/*********************************************************************332 *		Battery properties333 *********************************************************************/334static int olpc_bat_get_property(struct power_supply *psy,335				 enum power_supply_property psp,336				 union power_supply_propval *val)337{338	struct olpc_battery_data *data = power_supply_get_drvdata(psy);339	int ret = 0;340	u16 ec_word;341	uint8_t ec_byte;342	__be64 ser_buf;343 344	ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &ec_byte, 1);345	if (ret)346		return ret;347 348	/* Theoretically there's a race here -- the battery could be349	   removed immediately after we check whether it's present, and350	   then we query for some other property of the now-absent battery.351	   It doesn't matter though -- the EC will return the last-known352	   information, and it's as if we just ran that _little_ bit faster353	   and managed to read it out before the battery went away. */354	if (!(ec_byte & (BAT_STAT_PRESENT | BAT_STAT_TRICKLE)) &&355			psp != POWER_SUPPLY_PROP_PRESENT)356		return -ENODEV;357 358	switch (psp) {359	case POWER_SUPPLY_PROP_STATUS:360		ret = olpc_bat_get_status(data, val, ec_byte);361		if (ret)362			return ret;363		break;364	case POWER_SUPPLY_PROP_CHARGE_TYPE:365		if (ec_byte & BAT_STAT_TRICKLE)366			val->intval = POWER_SUPPLY_CHARGE_TYPE_TRICKLE;367		else if (ec_byte & BAT_STAT_CHARGING)368			val->intval = POWER_SUPPLY_CHARGE_TYPE_FAST;369		else370			val->intval = POWER_SUPPLY_CHARGE_TYPE_NONE;371		break;372	case POWER_SUPPLY_PROP_PRESENT:373		val->intval = !!(ec_byte & (BAT_STAT_PRESENT |374					    BAT_STAT_TRICKLE));375		break;376 377	case POWER_SUPPLY_PROP_HEALTH:378		if (ec_byte & BAT_STAT_DESTROY)379			val->intval = POWER_SUPPLY_HEALTH_DEAD;380		else {381			ret = olpc_bat_get_health(val);382			if (ret)383				return ret;384		}385		break;386 387	case POWER_SUPPLY_PROP_MANUFACTURER:388		ret = olpc_bat_get_mfr(val);389		if (ret)390			return ret;391		break;392	case POWER_SUPPLY_PROP_TECHNOLOGY:393		ret = olpc_bat_get_tech(val);394		if (ret)395			return ret;396		break;397	case POWER_SUPPLY_PROP_VOLTAGE_AVG:398	case POWER_SUPPLY_PROP_VOLTAGE_NOW:399		ret = olpc_ec_cmd(EC_BAT_VOLTAGE, NULL, 0, (void *)&ec_word, 2);400		if (ret)401			return ret;402 403		val->intval = ecword_to_cpu(data, ec_word) * 9760L / 32;404		break;405	case POWER_SUPPLY_PROP_CURRENT_AVG:406	case POWER_SUPPLY_PROP_CURRENT_NOW:407		ret = olpc_ec_cmd(EC_BAT_CURRENT, NULL, 0, (void *)&ec_word, 2);408		if (ret)409			return ret;410 411		val->intval = ecword_to_cpu(data, ec_word) * 15625L / 120;412		break;413	case POWER_SUPPLY_PROP_CAPACITY:414		ret = olpc_ec_cmd(EC_BAT_SOC, NULL, 0, &ec_byte, 1);415		if (ret)416			return ret;417		val->intval = ec_byte;418		break;419	case POWER_SUPPLY_PROP_CAPACITY_LEVEL:420		if (ec_byte & BAT_STAT_FULL)421			val->intval = POWER_SUPPLY_CAPACITY_LEVEL_FULL;422		else if (ec_byte & BAT_STAT_LOW)423			val->intval = POWER_SUPPLY_CAPACITY_LEVEL_LOW;424		else425			val->intval = POWER_SUPPLY_CAPACITY_LEVEL_NORMAL;426		break;427	case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:428		ret = olpc_bat_get_charge_full_design(val);429		if (ret)430			return ret;431		break;432	case POWER_SUPPLY_PROP_CHARGE_NOW:433		ret = olpc_bat_get_charge_now(val);434		if (ret)435			return ret;436		break;437	case POWER_SUPPLY_PROP_TEMP:438		ret = olpc_ec_cmd(EC_BAT_TEMP, NULL, 0, (void *)&ec_word, 2);439		if (ret)440			return ret;441 442		val->intval = ecword_to_cpu(data, ec_word) * 10 / 256;443		break;444	case POWER_SUPPLY_PROP_TEMP_AMBIENT:445		ret = olpc_ec_cmd(EC_AMB_TEMP, NULL, 0, (void *)&ec_word, 2);446		if (ret)447			return ret;448 449		val->intval = (int)ecword_to_cpu(data, ec_word) * 10 / 256;450		break;451	case POWER_SUPPLY_PROP_CHARGE_COUNTER:452		ret = olpc_ec_cmd(EC_BAT_ACR, NULL, 0, (void *)&ec_word, 2);453		if (ret)454			return ret;455 456		val->intval = ecword_to_cpu(data, ec_word) * 6250 / 15;457		break;458	case POWER_SUPPLY_PROP_SERIAL_NUMBER:459		ret = olpc_ec_cmd(EC_BAT_SERIAL, NULL, 0, (void *)&ser_buf, 8);460		if (ret)461			return ret;462 463		sprintf(data->bat_serial, "%016llx", (long long)be64_to_cpu(ser_buf));464		val->strval = data->bat_serial;465		break;466	case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:467		ret = olpc_bat_get_voltage_max_design(val);468		if (ret)469			return ret;470		break;471	default:472		ret = -EINVAL;473		break;474	}475 476	return ret;477}478 479static enum power_supply_property olpc_xo1_bat_props[] = {480	POWER_SUPPLY_PROP_STATUS,481	POWER_SUPPLY_PROP_CHARGE_TYPE,482	POWER_SUPPLY_PROP_PRESENT,483	POWER_SUPPLY_PROP_HEALTH,484	POWER_SUPPLY_PROP_TECHNOLOGY,485	POWER_SUPPLY_PROP_VOLTAGE_AVG,486	POWER_SUPPLY_PROP_VOLTAGE_NOW,487	POWER_SUPPLY_PROP_CURRENT_AVG,488	POWER_SUPPLY_PROP_CURRENT_NOW,489	POWER_SUPPLY_PROP_CAPACITY,490	POWER_SUPPLY_PROP_CAPACITY_LEVEL,491	POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,492	POWER_SUPPLY_PROP_CHARGE_NOW,493	POWER_SUPPLY_PROP_TEMP,494	POWER_SUPPLY_PROP_TEMP_AMBIENT,495	POWER_SUPPLY_PROP_MANUFACTURER,496	POWER_SUPPLY_PROP_SERIAL_NUMBER,497	POWER_SUPPLY_PROP_CHARGE_COUNTER,498	POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,499};500 501/* XO-1.5 does not have ambient temperature property */502static enum power_supply_property olpc_xo15_bat_props[] = {503	POWER_SUPPLY_PROP_STATUS,504	POWER_SUPPLY_PROP_CHARGE_TYPE,505	POWER_SUPPLY_PROP_PRESENT,506	POWER_SUPPLY_PROP_HEALTH,507	POWER_SUPPLY_PROP_TECHNOLOGY,508	POWER_SUPPLY_PROP_VOLTAGE_AVG,509	POWER_SUPPLY_PROP_VOLTAGE_NOW,510	POWER_SUPPLY_PROP_CURRENT_AVG,511	POWER_SUPPLY_PROP_CURRENT_NOW,512	POWER_SUPPLY_PROP_CAPACITY,513	POWER_SUPPLY_PROP_CAPACITY_LEVEL,514	POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,515	POWER_SUPPLY_PROP_CHARGE_NOW,516	POWER_SUPPLY_PROP_TEMP,517	POWER_SUPPLY_PROP_MANUFACTURER,518	POWER_SUPPLY_PROP_SERIAL_NUMBER,519	POWER_SUPPLY_PROP_CHARGE_COUNTER,520	POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,521};522 523/* EEPROM reading goes completely around the power_supply API, sadly */524 525#define EEPROM_START	0x20526#define EEPROM_END	0x80527#define EEPROM_SIZE	(EEPROM_END - EEPROM_START)528 529static ssize_t olpc_bat_eeprom_read(struct file *filp, struct kobject *kobj,530		struct bin_attribute *attr, char *buf, loff_t off, size_t count)531{532	uint8_t ec_byte;533	int ret;534	int i;535 536	for (i = 0; i < count; i++) {537		ec_byte = EEPROM_START + off + i;538		ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &buf[i], 1);539		if (ret) {540			pr_err("olpc-battery: "541			       "EC_BAT_EEPROM cmd @ 0x%x failed - %d!\n",542			       ec_byte, ret);543			return -EIO;544		}545	}546 547	return count;548}549 550static struct bin_attribute olpc_bat_eeprom = {551	.attr = {552		.name = "eeprom",553		.mode = S_IRUGO,554	},555	.size = EEPROM_SIZE,556	.read = olpc_bat_eeprom_read,557};558 559/* Allow userspace to see the specific error value pulled from the EC */560 561static ssize_t olpc_bat_error_read(struct device *dev,562		struct device_attribute *attr, char *buf)563{564	uint8_t ec_byte;565	ssize_t ret;566 567	ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);568	if (ret < 0)569		return ret;570 571	return sysfs_emit(buf, "%d\n", ec_byte);572}573 574static struct device_attribute olpc_bat_error = {575	.attr = {576		.name = "error",577		.mode = S_IRUGO,578	},579	.show = olpc_bat_error_read,580};581 582static struct attribute *olpc_bat_sysfs_attrs[] = {583	&olpc_bat_error.attr,584	NULL585};586 587static struct bin_attribute *olpc_bat_sysfs_bin_attrs[] = {588	&olpc_bat_eeprom,589	NULL590};591 592static const struct attribute_group olpc_bat_sysfs_group = {593	.attrs = olpc_bat_sysfs_attrs,594	.bin_attrs = olpc_bat_sysfs_bin_attrs,595 596};597 598static const struct attribute_group *olpc_bat_sysfs_groups[] = {599	&olpc_bat_sysfs_group,600	NULL601};602 603/*********************************************************************604 *		Initialisation605 *********************************************************************/606 607static struct power_supply_desc olpc_bat_desc = {608	.name = "olpc_battery",609	.get_property = olpc_bat_get_property,610	.use_for_apm = 1,611};612 613static int olpc_battery_suspend(struct platform_device *pdev,614				pm_message_t state)615{616	struct olpc_battery_data *data = platform_get_drvdata(pdev);617 618	if (device_may_wakeup(&data->olpc_ac->dev))619		olpc_ec_wakeup_set(EC_SCI_SRC_ACPWR);620	else621		olpc_ec_wakeup_clear(EC_SCI_SRC_ACPWR);622 623	if (device_may_wakeup(&data->olpc_bat->dev))624		olpc_ec_wakeup_set(EC_SCI_SRC_BATTERY | EC_SCI_SRC_BATSOC625				   | EC_SCI_SRC_BATERR);626	else627		olpc_ec_wakeup_clear(EC_SCI_SRC_BATTERY | EC_SCI_SRC_BATSOC628				     | EC_SCI_SRC_BATERR);629 630	return 0;631}632 633static int olpc_battery_probe(struct platform_device *pdev)634{635	struct power_supply_config bat_psy_cfg = {};636	struct power_supply_config ac_psy_cfg = {};637	struct olpc_battery_data *data;638	struct device_node *np;639	uint8_t status;640	uint8_t ecver;641	int ret;642 643	data = devm_kzalloc(&pdev->dev, sizeof(*data), GFP_KERNEL);644	if (!data)645		return -ENOMEM;646	platform_set_drvdata(pdev, data);647 648	/* See if the EC is already there and get the EC revision */649	ret = olpc_ec_cmd(EC_FIRMWARE_REV, NULL, 0, &ecver, 1);650	if (ret)651		return ret;652 653	np = of_find_compatible_node(NULL, NULL, "olpc,xo1.75-ec");654	if (np) {655		of_node_put(np);656		/* XO 1.75 */657		data->new_proto = true;658		data->little_endian = true;659	} else if (ecver > 0x44) {660		/* XO 1 or 1.5 with a new EC firmware. */661		data->new_proto = true;662	} else if (ecver < 0x44) {663		/*664		 * We've seen a number of EC protocol changes; this driver665		 * requires the latest EC protocol, supported by 0x44 and above.666		 */667		printk(KERN_NOTICE "OLPC EC version 0x%02x too old for "668			"battery driver.\n", ecver);669		return -ENXIO;670	}671 672	ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &status, 1);673	if (ret)674		return ret;675 676	/* Ignore the status. It doesn't actually matter */677 678	ac_psy_cfg.of_node = pdev->dev.of_node;679	ac_psy_cfg.drv_data = data;680 681	data->olpc_ac = devm_power_supply_register(&pdev->dev, &olpc_ac_desc,682								&ac_psy_cfg);683	if (IS_ERR(data->olpc_ac))684		return PTR_ERR(data->olpc_ac);685 686	if (of_device_is_compatible(pdev->dev.of_node, "olpc,xo1.5-battery")) {687		/* XO-1.5 */688		olpc_bat_desc.properties = olpc_xo15_bat_props;689		olpc_bat_desc.num_properties = ARRAY_SIZE(olpc_xo15_bat_props);690	} else {691		/* XO-1 */692		olpc_bat_desc.properties = olpc_xo1_bat_props;693		olpc_bat_desc.num_properties = ARRAY_SIZE(olpc_xo1_bat_props);694	}695 696	bat_psy_cfg.of_node = pdev->dev.of_node;697	bat_psy_cfg.drv_data = data;698	bat_psy_cfg.attr_grp = olpc_bat_sysfs_groups;699 700	data->olpc_bat = devm_power_supply_register(&pdev->dev, &olpc_bat_desc,701								&bat_psy_cfg);702	if (IS_ERR(data->olpc_bat))703		return PTR_ERR(data->olpc_bat);704 705	if (olpc_ec_wakeup_available()) {706		device_set_wakeup_capable(&data->olpc_ac->dev, true);707		device_set_wakeup_capable(&data->olpc_bat->dev, true);708	}709 710	return 0;711}712 713static const struct of_device_id olpc_battery_ids[] = {714	{ .compatible = "olpc,xo1-battery" },715	{ .compatible = "olpc,xo1.5-battery" },716	{}717};718MODULE_DEVICE_TABLE(of, olpc_battery_ids);719 720static struct platform_driver olpc_battery_driver = {721	.driver = {722		.name = "olpc-battery",723		.of_match_table = olpc_battery_ids,724	},725	.probe = olpc_battery_probe,726	.suspend = olpc_battery_suspend,727};728 729module_platform_driver(olpc_battery_driver);730 731MODULE_AUTHOR("David Woodhouse <dwmw2@infradead.org>");732MODULE_LICENSE("GPL");733MODULE_DESCRIPTION("Battery driver for One Laptop Per Child 'XO' machine");734